Timing Messages
Report Title | Timing Analysis Report |
Design File | \\wsl.localhost\Debian\home\koray\code\verilog\gowin\bttn\impl\gwsynthesis\bttn.vg |
Physical Constraints File | \\wsl.localhost\Debian\home\koray\code\verilog\gowin\bttn\src\bttn.cst |
Timing Constraint File | --- |
Tool Version | V1.9.9.03 Education (64-bit) |
Part Number | GW2A-LV18PG256C8/I7 |
Device | GW2A-18 |
Device Version | C |
Created Time | Tue Jan 21 15:29:17 2025 |
Legal Announcement | Copyright (C)2014-2024 Gowin Semiconductor Corporation. All rights reserved. |
Timing Summaries
STA Tool Run Summary:
Setup Delay Model | Slow 0.95V 85C C8/I7 |
Hold Delay Model | Fast 1.05V 0C C8/I7 |
Numbers of Paths Analyzed | 158 |
Numbers of Endpoints Analyzed | 14 |
Numbers of Falling Endpoints | 0 |
Numbers of Setup Violated Endpoints | 0 |
Numbers of Hold Violated Endpoints | 0 |
Clock Summary:
Clock Name | Type | Period | Frequency(MHz) | Rise | Fall | Source | Master | Objects |
---|
Max Frequency Summary:
NO. | Clock Name | Constraint | Actual Fmax | Logic Level | Entity |
---|
Total Negative Slack Summary:
Clock Name | Analysis Type | Endpoints TNS | Number of Endpoints |
---|
Timing Details
Path Slacks Table:
Setup Paths Table
Report Command:report_timing -setup -max_paths 25 -max_common_paths 1
Nothing to report!
Hold Paths Table
Report Command:report_timing -hold -max_paths 25 -max_common_paths 1
Nothing to report!
Recovery Paths Table
Report Command:report_timing -recovery -max_paths 25 -max_common_paths 1
Nothing to report!
Removal Paths Table
Report Command:report_timing -removal -max_paths 25 -max_common_paths 1
Nothing to report!
Minimum Pulse Width Table:
Number | Slack | Actual Width | Required Width | Type | Clock | Objects |
---|
Timing Report By Analysis Type:
Setup Analysis Report
Report Command:report_timing -setup -max_paths 25 -max_common_paths 1
No setup paths to report!
Hold Analysis Report
Report Command:report_timing -hold -max_paths 25 -max_common_paths 1
No hold paths to report!
Recovery Analysis Report
Report Command:report_timing -recovery -max_paths 25 -max_common_paths 1
No recovery paths to report!
Removal Analysis Report
Report Command:report_timing -removal -max_paths 25 -max_common_paths 1
No removal paths to report!
Minimum Pulse Width Report:
Report Command:report_min_pulse_width -nworst 10 -detail
Nothing to report!
High Fanout Nets Report:
Report Command:report_high_fanout_nets -max_nets 10
FANOUT | NET NAME | WORST SLACK | MAX DELAY |
---|
Route Congestions Report:
Report Command:report_route_congestion -max_grids 10
GRID LOC | ROUTE CONGESTIONS |
---|---|
R27C30 | 43.06% |
R29C29 | 43.06% |
R27C29 | 40.28% |
R26C29 | 33.33% |
R26C30 | 31.94% |
R29C28 | 30.56% |
R29C30 | 29.17% |
R27C28 | 26.39% |
R27C31 | 25.00% |
R26C28 | 25.00% |
Timing Exceptions Report:
Setup Analysis Report
Report Command:report_exceptions -setup -max_paths 5 -max_common_paths 1
No timing exceptions to report!
Hold Analysis Report
Report Command:report_exceptions -hold -max_paths 5 -max_common_paths 1
No timing exceptions to report!
Recovery Analysis Report
Report Command:report_exceptions -recovery -max_paths 5 -max_common_paths 1
No timing exceptions to report!
Removal Analysis Report
Report Command:report_exceptions -removal -max_paths 5 -max_common_paths 1
No timing exceptions to report!
Timing Constraints Report:
SDC Command Type | State | Detail Command |
---|