Timing Messages

Report Title Timing Analysis Report
Design File C:\Users\koray\Documents\gowin\ALU\impl\gwsynthesis\ALU.vg
Physical Constraints File C:\Users\koray\Documents\gowin\ALU\src\top.cst
Timing Constraint File ---
Tool Version V1.9.10.03 (64-bit)
Part Number GW2A-LV18PG256C8/I7
Device GW2A-18
Created Time Thu Jan 23 05:43:13 2025
Legal Announcement Copyright (C)2014-2024 Gowin Semiconductor Corporation. All rights reserved.

Timing Summaries

STA Tool Run Summary:

Setup Delay Model Slow 0.95V 85C C8/I7
Hold Delay Model Fast 1.05V 0C C8/I7
Numbers of Paths Analyzed 158
Numbers of Endpoints Analyzed 14
Numbers of Falling Endpoints 0
Numbers of Setup Violated Endpoints 0
Numbers of Hold Violated Endpoints 0

Clock Summary:

NO. Clock Name Type Period Frequency(MHz) Rise Fall Source Master Objects

Max Frequency Summary:

NO. Clock Name Constraint Actual Fmax Logic Level Entity

Total Negative Slack Summary:

Clock Name Analysis Type Endpoints TNS Number of Endpoints

Timing Details

Path Slacks Table:

Setup Paths Table

Report Command:report_timing -setup -max_paths 25 -max_common_paths 1

Nothing to report!

Hold Paths Table

Report Command:report_timing -hold -max_paths 25 -max_common_paths 1

Nothing to report!

Recovery Paths Table

Report Command:report_timing -recovery -max_paths 25 -max_common_paths 1

Nothing to report!

Removal Paths Table

Report Command:report_timing -removal -max_paths 25 -max_common_paths 1

Nothing to report!

Minimum Pulse Width Table:

Report Command:report_min_pulse_width -nworst 10 -detail

Nothing to report!

Number Slack Actual Width Required Width Type Clock Objects

Timing Report By Analysis Type:

Setup Analysis Report

Report Command:report_timing -setup -max_paths 25 -max_common_paths 1

No setup paths to report!

Hold Analysis Report

Report Command:report_timing -hold -max_paths 25 -max_common_paths 1

No hold paths to report!

Recovery Analysis Report

Report Command:report_timing -recovery -max_paths 25 -max_common_paths 1

No recovery paths to report!

Removal Analysis Report

Report Command:report_timing -removal -max_paths 25 -max_common_paths 1

No removal paths to report!

Minimum Pulse Width Report:

Report Command:report_min_pulse_width -nworst 10 -detail

Nothing to report!

High Fanout Nets Report:

Report Command:report_high_fanout_nets -max_nets 10

FANOUT NET NAME WORST SLACK MAX DELAY

Route Congestions Report:

Report Command:report_route_congestion -max_grids 10

GRID LOC ROUTE CONGESTIONS
R29C29 51.39%
R27C29 36.11%
R27C30 36.11%
R29C28 33.33%
R29C30 30.56%
R26C30 30.56%
R27C28 29.17%
R30C28 27.78%
R26C28 27.78%
R26C29 27.78%

Timing Exceptions Report:

Setup Analysis Report

Report Command:report_exceptions -setup -max_paths 5 -max_common_paths 1

No timing exceptions to report!

Hold Analysis Report

Report Command:report_exceptions -hold -max_paths 5 -max_common_paths 1

No timing exceptions to report!

Recovery Analysis Report

Report Command:report_exceptions -recovery -max_paths 5 -max_common_paths 1

No timing exceptions to report!

Removal Analysis Report

Report Command:report_exceptions -removal -max_paths 5 -max_common_paths 1

No timing exceptions to report!

Timing Constraints Report:

SDC Command Type State Detail Command